The SHS1000 series is a multifunction handheld 2-channel oscilloscope that also includes a full digital multimeter logger and a waveform recorder. Siglent’s patented Isolated Channel technology provides isolation from ground and between channels. With a signal bandwidth of 60MHz or 100MHz, this portable unit with a bright 5.7” color TFT LCD screen can measure at a real-time sample rate of 1GSa/s with a memory depth of 2Mpts, allowing storing, replaying and zooming in on measurements.

The oscilloscope features multiple trigger types (Edge, Pulse, Video, Slope and Alternative), a rise time of less than 5.8ns, vertical sensitivity of 5mV/div – 100V/div and 8 bit vertical resolution.  The built-in multimeter of the SHS1000 series can also measure DC/AC voltage, DC/AC current, resistance, capacitance, diode and continuity in many ranges with a display count of 6000.  The SHS1000's built in data-recorder has up to 18 hours recording time, while the Meter TrendPlot can record multimeter measurement data for as long as 6000 hours at 0.05Sa/s. 

Input voltage: input voltage through BNC is up to CATII 300V and CATIII 150V Standard probe: 10X CAT II 400V Optional probe: 10X CAT II 1000V and 10X CAT III 600V Oscilloscope and multimeter safety to CAT II 600V and CAT III 300V.

The SHS1000 series offers 32 automatic measurements,3 cursor measure modes, 4 digital filters (low-pass, high-pass, band-pass, band-limit) as well as Math functions +, -, ×, ÷, and X/Y plots, as well as FFT frequency display.  Multiple trigger types include video signal settings.

It features USB device for software updates, and USB host capabilities for PictBridge-compatible printers. SHS1000 connects to a PC through a USB cable for EasyScope control software and can save/recall waveforms to USB Flash drive. SHS1000 can save 2 groups of reference waveforms, 20 groups of setups and 10 groups of waveforms in its internal memory, save setup data, waveform data, waveform interface image, and CSV file to an USB flash drive.

The SHS1000 comes with a rechargeable 7.4V 5000mAh Lithium battery pack which lasts up to 5 hours of continuous use, but a 100-240V 50/60Hz 9V 4A DC adapter is also provided.  Two 100MHz oscilloscope probes (1 x CAT II 1000V and 1 x CAT III 600V) are included too, as well as two test leads for multimeter measurements.

  • 2-channel device
  • Includes IsolatedChannel technology that isolates ground and between channels
  • 5.7 inch colour LCD display
  • 60 or 100MHz bandwidth
  • 6000 count multimeter measures DC/AC Voltage, DC/AC current, Resistance, Diode, Capacitance and Continuity
  • Includes Trendplot, Meter Trendplot and Scope recording functions
  • Automatic and manual trigger modes
  • Trigger types: Edge, Pulse, Video, Slope and Alternative
  • 32 automatic waveform measurements, 3 cursor measure modes
  • Digital filter functions: high pass, band pass, band limit
  • Mathematical functions: +, -, x, ÷ and FFT
  • Multiple language user interface
  • USB device and USB host with PC communication
  • Rechargeable battery
  • Ideal for multiple applications including power electronics, industrial power systems, field testing and more

Model

SHS1062

SHS1102

Bandwidth

60MHz

100MHz

Rise Time

≤5.8ns

≤3.5ns

Real Time Sampling Rate

Single Channel: 1GSa/s, 
Dual Channels: 500MSa/s

Single Channel: 1GSa/s, 
Dual Channels: 500MSa/s

Equivalent Sampling Rate

50GSa/s

50GSa/s

Memory Depth

2Mpts

2Mpts

Time Base Range

5 ns/ div – 50s/ div

2.5ns/ div – 50s/ div

Scan Range

100ms/ div ~ 50s/ div

100ms/ div ~ 50s/ div

Vertical Sensitivity

5mV/div – 100V/div(1-2-5 order)

5mV/div – 100V/div(1-2-5 order)

Vertical Resolution

8 bits

8 bits

Trigger Types

Edge, Pulse, Video, Slope, Alternative

Edge, Pulse, Video, Slope, Alternative

Frequency Counter

6 bits

6 bits

Connection

USB Device, USB Host

USB Device, USB Host

Math

+, -, * , /, FFT

+, -, * , /, FFT

Oscilloscope Trend Plot

800K points

Meter

Maximum Resolution

6000

DC Voltage

60mV 
600mV—1000V

(±1%±15digit)
(±1%±5digit)

AC Voltage

60mV
600mV—750V

(±1%±15digit)
(±1%±5digit)

DC Current

60.00mA—600mA
6A—10A

(±1%±5digit)
(±1.5%±5digit)

AC Current

60.00mA—600mA
6A—10A

(±1%±5digit)
(±1.5%±5digit)

Resistance

600Ω—60MΩ

(±1%±5digit)

Capacitance

40nF
400nF--400uF

(±3%±10digit)
(±4%±5digit)

Diode

0—2V

Continuity

<50Ω Buzzer sounds

Multimeter Trend Plot

1.2M points

channels from earth ground,

between two channels

references

Overvoltage Category

Maximum Voltage

CAT I&CAT II

1000 Vrms

CAT ?

600 Vrms

between Multimeter input

reference and the ground

Overvoltage Category

Maximum Voltage

CAT I&CAT II

600 Vrms

CAT III

300 Vrms

Max. input Voltage for BNC

Overvoltage Category

Maximum Voltage

1x CAT I&CAT II

300 Vrms

1X CAT III

150 Vrms

10x CAT I&CAT II

1000 Vrms

10X CAT III

600 Vrms

Max. input Voltage for
Multimeter input port

Voltage port

DC 1000V, AC 750V

Current port(mA)

AC 250V/600mA

Current port(A)

AC 250V/10A

Single Channel Common
Mode Rejection, typical

>1000:1 50MHz

Channel-to-Channel Isolation

>35 dB

 

General Feature

Display 

5.7 inch color TFT-LCD, 320x234 

Power supply 

With battery or DC adapter 

Power source 

Built-in rechargeable lithium battery: 7.4V 5000mAh, Battery persisting 4 hours With DC adapter: 100-240V 50/60Hz input 9V 4A output. 

Weight 

1.5Kg  (3.3lb) 

Dimension 

163.2mm×259.5mm×53.3mm  (6.5” x 10.2” x 2.1”)