• 2 kW to 10 kW in a 2U package
  • Models from 0-5 VDC to 0-10,000 VDC
  • Optically isolated user I/O circuitry standard
  • High efficiency operation: Up to 88% efficiency on select models
  • RS-232 interface standard with SCPI Commands
  • Optional GPIB, USB, Ethernet (LXI-C), RS-485 interfaces
  • Over Voltage and Over Current shutdown standard
  • Certified LabWindows/CVI, LabVIEW, and IVI Drivers
  • Programmable Output Modulation: Emulates user-defined power profiles
  • Automatic Voltage/Current Crossover
  • Front Panel Calibration 
  • Made in USA
  • Two Year Warranty

Magna-Power Electronics XR Series IV was designed from the ground up for high reliability and industry leading 2U (3.5" height) rack-mount power density, with output isolation up to 1000 Vdc for models rated for 1000 Vdc and below. This product series utilizes Magna-Power Electronics signature current-fed power processing, delivering robust power conversion with a high power factor—greater than 0.92 for 3Φ units. Soft-start circuitry on the input minimizes in-rush current to levels below the rated input current. High accuracy programming and monitoring levels allow confi - dence in power supply measurements, eliminating the need for external power meters.

All XR Series IV power supplies come standard with isolated 37-pin external I/O, RS-232, Remote Interface Software, IVI drivers for integration into a variety of programming environments, and modulation capabilities for non-linear output profile emulation. Two front panel types are available for different application requirements. The standard XR Version front panel (pictured in the image above) provides front panel control knobs and calibration, start and stop buttons, and a digital display for voltage and current. The C Version front panel provides a blank display panel, allowing control only from the computer or isolated 37-pin I/O connection.

Electronic Output Stage
The new and novel XR Series output stage utilizes constant power loading under all conditions via an electronic bleed resistance. This electronic bleeder means stability under all operating conditions and faster fall times, without affecting the overall system efficiency.

Fully Configurable
XR Series power supplies can be configured through the front panel for different applications. The power supply can be programmed to have its control functions accessible from the front panel, rear connector, RS-232, optional GPIB, optional USB, or optional LXI-certified Ethernet communications. Sensing can be established at the output terminal of the power supply or through a rear terminal block for sensing at the load. An external interlock can be set to enable operation only when an external connection is made. Even calibration has been simplified with front panel access to calibration digital potentiometers.

Isolated External I/O for Automation
Using the rear 37-pin I/O connector, the XR Series power supplies can be completely controlled and monitored using external signals. The voltage, current, over voltage trip, and over current trip set points are set by applying a 0-10 Vdc signal. Each diagnostic condition is given a designated pin, which reads 5 Vdc when high. In addition, reference 5 Vdc and 10 Vdc signals are provided, eliminating the need for external voltage signals and allowing the use of dry contacts. Also, the power supply features an external interlock, which when enabled, allows the power supply to be tied in with other emergency stop equipment. All these pins are isolated to earth-ground as standard--no additional isolation equipment or options necessary.

Designed for Safety
The XR Series power supplies have extensive diagnostic functions—all of which, when activated, take command to shut down the system. Diagnostic functions include phase loss, excessive thermal conditions, over voltage trip, over current trip, fuse clearing, and program line. Program line monitors externally applied analog set point signals to insure they are within the specified range. Upon a diagnostic fault condition, main power is disconnected and the diagnostic condition is latched into memory. Pressing the clear key clears the memory. All diagnostic functions can be monitored through a rear connector. Furthermore, control functions can also be set through the rear connector to allow simultaneous control of one or more XR Series units. XR Series supplies have three levels of over voltage/current protection: shutdown of controlling insulated gate bipolar transistors (IGBTs), disconnect of main power, and input fuses. After an over voltage/current trip condition, the supply must be reset.

XR Version Standard Front Panel
XR models provide stepless analog control from front panel potentiometers. With a simple configuration change, the power supply can be programmed from the rear I/O connector or through software on one of the communications bus. The XR Series has 100 memory states available to program voltage, current, over voltage trip, over current trip, and time period in software. More Info >> 

XRC Version Front Panel
XRC models only allow control from the rear connector or by RS-232/GPIB/Ethernet communications. These models are intended for process control applications where front panel controls and displays are not required or desired. More Info >

 

Magna-Power SoftwareRemote Interface Software
The Remote Interface Software (RIS Panel) ships with all XR Series power supplies. The software provides the user with a quick method to operate a Magna-Power Electronics' power supply under computer control. The Remote Interface Software has six windows: the Virtual Control Panel, Command Panel, Register Panel, Calibration Panel, Firmware Panel, and Modulation Panel. The Virtual Control Panel emulates the front panel of the XR Series power supply, the Command panel programs and reads SCPI commands with user friendly buttons, the Register Panel programs and reads registers, the Calibration Panel enables calibration of the digital potentiometers, the Firmware Panel enables the program stored internal to the power supply to be upgraded, and the Modulation Panel eases programming of modulation parameters.

Models Ordering Guide

XR Ordering Guide

Models Chart

The following chart details the available standard XR Series models. The Current Maximum (Adc) column is separated by the available power levels. To determine the appropriate model, first select your output Voltage Maximum (Vdc) to find appropriate row. Next, select one desired Current Maximum from the row that contains your desired Voltage Maximum. Then, construct your model number according to the model ordering guide above.

  2 kW 4 kW 6 kW 8 kW 10 kW  
Voltage
Maximum
Current Maximum Ripple*
(mVrms)
Efficiency (%)
5 375 600 N/A N/A N/A 50 86
10 200 375 600 N/A N/A 50 86
16 125 250 375 500 600 50 86
20 100 200 300 375 500 45 86
32 62 124 186 250 310 40 86
40 50 100 150 200 250 40 87
50 40 80 120 160 200 50 87
80 25 50 75 100 125 60 87
100 20 40 60 80 100 60 87
125 16 32 48 64 80 100 87
160 12 24 36 50 60 120 87
200 10 20 30 40 50 125 87
250 8 16 24 32 40 130 88
375 5.3 10.6 15.9 21.3 26.5 170 88
400 5.0 10.0 15.0 20.0 25 180 88
500 4.0 8.0 12.0 16.0 20 220 88
600 3.3 6.6 9.9 13.3 16.5 250 88
800 2.5 5.0 7.5 10.0 12.5 300 88
1000 2.0 4.0 6.0 8.0 10 350 88
2000 1.00 2.00 3.00 4.00 N/A 5500 88
4000 0.50 1.00 1.50 2.00 N/A 6500 88
6000 0.30 0.66 1.00 1.33 N/A 7500 88
8000 0.25 0.50 0.75 1.00 N/A 8500 88
10000 0.20 0.40 0.60 0.80 N/A 9500 88

16 Aac input current for 208/240 Vac, 1Φ input (optional for 2 kW models only). 
Models above 1000 Vdc have high slew rate output. 
For models 1000 Vdc and below with the High Slew Rate Output Option (+HS), ripple will be higher.

* Outputs over 1000 Vdc are not isolated. At time of order, must specify positive (POS) of negative (NEG) output terminal grounded. Example: XR10000-0.60/480NEG+LXI.

Input Voltage (Must be specified at time of order) 

1 phase, 2 wire + ground (for 2 kW models only) 
208 VAC, 1φ (operating range 187 - 229 VAC)
240 VAC, 1φ (operating range 216 - 264 VAC)

3 phase, 3 wire + ground (all models) 
208 VAC, 3φ (operating range 187 - 229 VAC)
240 VAC, 3φ (operating range 216 - 264 VAC)
380 VAC, 3φ (operating range 342 - 418 VAC)
415 VAC, 3φ (operating range 373 - 456 VAC)
440 VAC, 3φ (operating range 396 - 484 VAC)
480 VAC, 3φ (operating range 432 - 528 VAC)

NOTE: 

  • GPIB and Ethernet are optional and must be specified at time of order.
  • Power cords are not included.